Honeywell / RAE Systems Photoionization Detector (PID) / Compound-Specific Monitor UltraRAE 3000 PGM-7360, part no: 059-D316-000
The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID)extended range of 0.01 to 10,000 ppm in VOC mode and 10 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications, from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.

Dual detection mode for total benzene exposure assessment: 60-second snapshot or 15-minute STEL measurement
High sensitivity to benzene (as low as 10 ppb) provides a lower detection range for future benzene exposure limits
Lower risk of false alarms through advanced speciation method
Total VOC measurement mode with extended range of 0.05 to 10,000 ppm
267,150,000 ₫ 267150000.0 VND
Honeywell / RAE Systems Photoionization Detector (PID) / Compound-Specific Monitor UltraRAE 3000 PGM-7360, part no: 059-D316-200
The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID)extended range of 0.01 to 10,000 ppm in VOC mode and 10 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications, from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.

Dual detection mode for total benzene exposure assessment: 60-second snapshot or 15-minute STEL measurement
High sensitivity to benzene (as low as 10 ppb) provides a lower detection range for future benzene exposure limits
Lower risk of false alarms through advanced speciation method
Total VOC measurement mode with extended range of 0.05 to 10,000 ppm
291,000,000 ₫ 291000000.0 VND
Honeywell / RAE Systems Photoionization Detector (PID) / Compound-Specific Monitor UltraRAE 3000 PGM-7360, part no: 059-D31E-200
The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID)extended range of 0.01 to 10,000 ppm in VOC mode and 10 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications, from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.

Dual detection mode for total benzene exposure assessment: 60-second snapshot or 15-minute STEL measurement
High sensitivity to benzene (as low as 10 ppb) provides a lower detection range for future benzene exposure limits
Lower risk of false alarms through advanced speciation method
Total VOC measurement mode with extended range of 0.05 to 10,000 ppm
307,350,000 ₫ 307350000.0 VND
747,000 ₫ 747000.0 VND
Pump Replacement For MiniRae 2000 / Thay Thế Bơm Cho MiniRae 2000
The Pump Replacement for MiniRae 2000 is designed to restore the functionality of the MiniRae 2000 gas detector. It ensures that the pump mechanism, which draws air samples into the detector, operates correctly. Replacing the pump helps maintain accurate gas detection and reliable performance.
15,066,000 ₫ 15066000.0 VND